Heat ShrinKable Busbar Insulating Tube

Model:
Brand:

Avoid short circuit fault caused by small animals such as mice, snakes etc. Prevent busbar from chemical corrosion effected by strong acid, alkali, salt etc. Avoid accidental injure to overhaul persons when they enter electriferous clearance by mistakes.
Provide excellent insulation performance to supply enquired flashover protection for the basbar system. Solve the problem of insulating among busbars in bus trough.
Color: red, yellow, green, black.

1KV WMPG

Model

Applicable Busbar

Before Shrink

After Shrank

Width(mm)

I.D.(mm)

Layer Thickness(mm)

I.D.(mm)

Layer thickness(mm)

1KV WMPG 30

30

31.5±1.0

0.45±0.15

15

0.95±0.15

1KV WMPG 35

40

37.0±1.5

0.50±0.15

16

1.00±0.15

1KV WMPG 40

40

40.5±1.5

0.50±0.15

20

1.00±0.15

1KV WMPG 50

50

50.5±2.0

0.50±0.15

25

1.00±0.15

1KV WMPG 60

60

60.0±3.0

0.80±0.20

30

1.30±0.20

1KV WMPG 70

80

70.0±3.0

0.80±0.20

32

1.50±0.20

1KV WMPG 80

80/100

80.0±3.0

0.80±0.30

40

1.50±0.30

1KV WMPG 90

100

90.0±4.0

0.80±0.30

43

1.50±.030

1KV WMPG 100

100/120

100±4.0

0.80±0.30

50

1.50±0.30

1KV WMPG 120

150

120±4.0

0.80±0.30

60

1.50±0.30

1KV WMPG 150

180

150±4.0

0.80±0.30

75

1.50±0.30


10KV WMPG

Model

Applicable Busbar

Before Shrink

After Shrank

Width (mm)

I.D. (mm)

Layer Thickness(mm)

I.D.(mm)

Layer thickness(mm)

10KV WMPG 20

20

20±0.8

1.0±0.2

9

2.2±0.2

10KV WMPG 30

30

30±0.8

1.0±0.2

13

2.2±0.2

10KV WMPG 40

40

40±1.0

1.2±0.2

15

2.2±0.2

10KV WMPG 50

50

50±2.0

1.2±0.2

20

2.5±0.2

10KV WMPG 60/65

60

65±3.0

1.2±0.2

24

3.0±0.2

10KV WMPG 80

80/100

80±3.0

1.2±0.3

32

3.0±0.3

10KV WMPG 100

100/120

100±4.0

1.2±0.3

40

3.0±0.3

10KV WMPG 120

150

120±4.0

1.2±0.3

48

3.0±0.3

10KV WMPG 150

200

150±4.0

1.2±0.3

60

3.0±0.3

10KV WMPG 180

Max.

180±5.0

1.2±0.3

70

3.0±0.3

10KV WMPG 210

Max.

210±5.0

1.2±0.3

80

3.0±0.3


35KV WMPG

Model

Applicable Busbar

Before Shrink

After Shrank

Width(mm)

I.D.(mm)

Layer Thickness(mm)

I.D.(mm)

Layer thickness(mm)

35KV WMPG 30

30

30±1.0

2.0±0.3

13

4.0±0.3

35KV WMPG 40

40

40±1.0

2.0±0.3

15

4.0±0.3

35KV WMPG 50

50

50±2.0

2.2±0.3

20

4.5±0.3

35KV WMPG 60/65

60

60±2.0

2.2±0.3

24

4.5±0.3

35KV WMPG 80

80/100

80±3.0

2.2±0.3

32

4.5±0.3

35KV WMPG 100

100/120

100±4.0

2.5±0.3

40

4.5±0.3

35KV WMPG 120

150

120±4.0

2.5±0.3

48

5.0±0.3

35KV WMPG 150

200

150±4.0

2.5±0.3

60

5.0±0.3

35KV WMPG 180

Max.

180±5.0

2.5±0.3

70

5.0±0.3

35KV WMPG 210

Max.

210±5.0

2.5±0.3

80

5.0±0.3

Eliminate short circuit faults caused by small animals such as rats and snakes. Prevent the corrosion of acid, alkali, salt and other chemicals to the busbar. Prevent maintenance personnel from accidentally entering the live gap and causing accidental injury. Adapt to the development trend of miniaturization of switchgear. Solve the problem of phase to phase insulation of bus duct.