PRODUCTS
Location:Home > PRODUCTS > Coating Measurement Meters > Coating thickness Gages series > Dual-use Coating Thickness MCT200 (Integration)
Dual-use Coating Thickness MCT200 (Integration)
Use magnetic sensors to measure non ferromagnetic coatings and coatings on ferromagnetic metal substrates such as steel and iron, such as paint, powder, plastic, rubber, synthetic materials, phosphating layer, chromium, zinc, lead, aluminum, tin, cadmium, porcelain, enamel, oxide layer, etc.
Eddy current sensor is used to measure enamel, rubber, paint and plastic layers on copper, aluminum, zinc, tin and other substrates.
(Integration of the sensor coating thickness)
Function | Measure magnetic objects and non-magnetic coatings on non-magnetic metal matrix of non-conductive coating thickness |
Methods of measurem-ent | F magnetic induction; NF eddy current |
Measuring range | 0-1250 µm/0-50mil(standard range) |
Minimal surface | F: convex 1.5mm / concave 25mm; N: Convex: 3mm / concave 50mm |
Resolution | 0.1µm/1mil |
Minimum measuring area | 6mm² |
Thinnest base | 0.3mm |
Environment | Temperature :0-40 ℃; humidity :10-90% RH |
Accuracy | ± (1 ~ 3%) or ± 2 μm |
Power | 4 7# battery |
Battery voltage indication | Low Voltage tips |
weight | 81g (without battery) |
Dimensions | 126*65*27mm |
Optional Accessories | RS-232 or online and software |
Automatic shutdown | |
Bluetooth communications and software | |
Metric / Imperial | Optional |
It is widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields.